Battery parameters
The Toyota FJ Cruiser has 17 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
+BM voltage FJ_BM_V
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 2006, 2008 to 2014
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
In testing for 2006, 2008 to 2014. Supported for 2007.
Battery current FJ_BAT_CURRENTConfirmed
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing for 2006, 2009 to 2014
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 50 ÷ 13107 − 125)- Range
- -125 to 124.9 A
- Unit
- A
Confirmed for 2007 to 2008. In testing for 2006, 2009 to 2014.
Battery temperature FJ_BAT_T
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing for 2006, 2009 to 2014
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 6513.5 °C
- Unit
- °C
In testing for 2006, 2009 to 2014. Supported for 2007.
Battery voltage FJ_BAT_VConfirmed
- Request
21 13 - Service 21
PID 13 - Module
7C0 → 7C8 - Every
5 s - Testing for 2006 to 2011, 2014
Example reply from a 2013 Toyota FJ Cruiser.
Bits 0 to 7 of the reply, 8 bits.
0x84 = 132 → (132 ÷ 10) = 13.2 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2012 to 2013. In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010.
Battery voltage FJ_BATTERY_VOLTAGE_7E0Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2006, 2009, 2011, 2014
Example reply from a 2013 Toyota FJ Cruiser.
Bits 192 to 207 of the reply, 16 bits.
0x3345 = 13125 → (13125 ÷ 1000) = 13.125 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
Confirmed for 2010, 2012 to 2013. In testing for 2006, 2009, 2011, 2014. Supported for 2007 to 2008.
Charge contactor current FJ_SCC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2010, 2013. Supported for 2007 to 2008, 2011.
Main connector solenoid current FJ_SMC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.
Main relay a, solenoid current FJ_SLA_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.
Main relay r solenoid current FJ_SLR_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.
Output speed sensor voltage FJ_NOUT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2006, 2008 to 2014. Not supported for 2007.
Regenerative braking cooperation FJ_REGEN_COOPERATION
- Request
21 58 - Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.
Regenerative operation FJ_FR_REGEN_OPERATION
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.
Regenerative request FJ_FR_REGEN_REQUEST
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.
Relay control solenoid current FJ_SRC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.
Service contactor solenoid current FJ_SSC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2006, 2009, 2011, 2014. Not supported for 2007 to 2008, 2010, 2012 to 2013.
Turbine speed sensor voltage FJ_NT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 2006, 2008 to 2014. Not supported for 2007.