Ford F-150 Lightning

Climate parameters

The Ford F-150 Lightning has 6 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor current LIGHTNING_AC_COMP_AConfirmed

  • Request22 99 AB
  • Service 22DID 99AB
  • Module7C7 → 7CF
  • Every5 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 100 ÷ 32767) = 0 A

Formula
(val × 100 ÷ 32767)
Range
-100 to 100 A
Unit
A

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor current LIGHTNING_AC_COMP_AConfirmed

  • Request22 99 AB
  • Service 22DID 99AB
  • Module7C7 → 7CF
  • Every5 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 100 ÷ 32767) = 0 A

Formula
(val × 100 ÷ 32767)
Range
-100 to 100 A
Unit
A

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2024. Supported for 2025.

Coolant heater operation mode LIGHTNING_COOLANT_HTR_OP_MODEConfirmed

  • Request22 48 DF
  • Service 22DID 48DF
  • Module7E6 → 7EE
  • Every10 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → OFF

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ONOn
2DEGRADEDDegraded
3SHUTDOWNShutdown
4SHORTShort
5NO_RESPONSENo response
6UNKNOWNUnknown
7STOPStop

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Coolant heater power LIGHTNING_COOLANT_HTR_PWRConfirmed

  • Request22 48 DE
  • Service 22DID 48DE
  • Module7E6 → 7EE
  • Every5 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 1000) = 0 kW

Formula
(val ÷ 1000)
Range
0 to 65.535 kW
Unit
kW

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Exterior temperature LIGHTNING_AATConfirmed

  • Request22 DD 05
  • Service 22DID DD05
  • Module7E2 → 7EA
  • Every5 s

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 7 of the reply, 8 bits.

0x14 = 20 → (20 − 40) = -20 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2025. Not supported for 2003.

Interior temperature LIGHTNING_IATConfirmed

  • Request22 DD 04
  • Service 22DID DD04
  • Module7E2 → 7EA
  • Every5 s

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 7 of the reply, 8 bits.

0x20 = 32 → (32 − 40) = -8 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2025. Not supported for 2003.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.