Ford F-150 Lightning

Engine parameters

The Ford F-150 Lightning has 30 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine run time LIGHTNING_RUN_TIMEConfirmed

  • Request22 F4 1F
  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits.

0x002F = 47 → 47 s

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2022 to 2025.

Battery current LIGHTNING_BAT_CURRENT_726

  • Request22 40 90
  • Service 22DID 4090
  • Module726 → 72E
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16 − 511.7)
Range
-511.7 to 3584.2375 A
Unit
A

In testing for 2003, 2022, 2024. Not supported for 2023, 2025.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2022 to 2025.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2025.

Engine coolant temperature 1 ECT_1SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2024. Supported for 2025.

Engine coolant temperature 2 ECT_2SAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022 to 2024. Supported for 2025.

Engine run time LIGHTNING_RUN_TIMEConfirmed

  • Request22 F4 1F
  • Service 22DID F41F
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits.

0x002F = 47 → 47 s

Formula
val
Range
0 to 65535 s
Unit
s

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Forward sensing camera alignment offset LIGHTNING_FSM_AUTOMATICConfirmed

  • Request22 A2 20
  • Service 22DID A220
  • Module764 → 76C
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 10) = 0 °

Formula
(val ÷ 10)
Range
-3276 to 3276 °
Unit
°

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Grill shutter position LIGHTNING_GRILL_SHUTTER_POSITIONConfirmed

  • Request22 05 80
  • Service 22DID 0580
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 7 of the reply, 8 bits.

0x33 = 51 → (51 × 100 ÷ 255) = 20 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

High voltage current LIGHTNING_HIGH_V_CURRENTConfirmed

  • Request22 48 0B
  • Service 22DID 480B
  • Module7E2 → 7EA
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0054 = 84 → (84 ÷ 50) = 1.68 A

Formula
(val ÷ 50)
Range
-655 to 655 A
Unit
A

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

High voltage leakage resistance bus negative, raw count LIGHTNING_HIGH_V_LEAKAGE_RESConfirmed

  • Request22 48 12
  • Service 22DID 4812
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits.

0xB846 = 47174 → 47,174

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

High voltage leakage resistance bus overall, raw count LIGHTNING_HIGH_V_LEAKAGE_RES_BUSConfirmed

  • Request22 48 13
  • Service 22DID 4813
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits.

0xB846 = 47174 → 47,174

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

High voltage leakage resistance bus positive, raw count LIGHTNING_HIGH_V_LEAKAGE_RES_BUS_POSITIVEConfirmed

  • Request22 48 11
  • Service 22DID 4811
  • Module7E4 → 7EC
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits.

0xBFD2 = 49106 → 49,106

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

In car temperature LIGHTNING_CAR_T

  • Request22 DD 04
  • Service 22DID DD04
  • Module726 → 72E
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 8)
Range
0 to 31.875 °C
Unit
°C

In testing for 2003, 2022, 2024. Not supported for 2023, 2025.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2022 to 2024. Supported for 2025.

Outdoor temperature, BCM LIGHTNING_OUTDOOR_T_BCMConfirmed

  • Request22 DD 05
  • Service 22DID DD05
  • Module760 → 768
  • Every5 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 7 of the reply, 8 bits.

0x3D = 61 → (61 − 40) = 21 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Outside temperature LIGHTNING_OUTSIDE_TConfirmed

  • Request22 DD 05
  • Service 22DID DD05
  • Module7E6 → 7EE
  • Every5 s
  • Testing for 2003, 2022

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 7 of the reply, 8 bits.

0x3D = 61 → (61 × 9 ÷ 5 − 40) = 69.8 °F

Formula
(val × 9 ÷ 5 − 40)
Range
-40 to 419 °F
Unit
°F

Confirmed for 2023 to 2025. In testing for 2003, 2022.

Steering angle, actual value LIGHTNING_BCM_STEER_ANG_ACTConfirmed

  • Request22 33 02
  • Service 22DID 3302
  • Module760 → 768
  • Every250 ms
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits.

0x1C84 = 7300 → (7300 ÷ 10 − 780) = -50 °

Formula
(val ÷ 10 − 780)
Range
-780 to 5773 °
Unit
°

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Steering shaft torque LIGHTNING_STEER_SHFT_TQConfirmed

  • Request22 33 0C
  • Service 22DID 330C
  • Module730 → 738
  • Every250 ms
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 7 of the reply, 8 bits.

0x65 = 101 → (101 ÷ 10 − 12.7) = -2.6 N·m

Formula
(val ÷ 10 − 12.7)
Range
-12.7 to 12.8 N·m
Unit
N·m

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Yaw rate signal LIGHTNING_YAW_RATE_SIGConfirmed

  • Request22 2B 0B
  • Service 22DID 2B0B
  • Module760 → 768
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 5) = 0

Formula
(val ÷ 5)
Range
-6553 to 6553
Unit
Raw value

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Engine › Internal

Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2022 to 2024. Supported for 2025.

Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed

  • Request01 67
  • Service 01PID 67
  • Module7E0 → 7E8
  • Every1 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
Number

Confirmed for 2022 to 2024. Supported for 2025.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2024. Supported for 2025.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2024. Supported for 2025.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2024. Supported for 2025.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2024. Supported for 2025.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2024. Supported for 2025.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2024. Supported for 2025.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2024. Supported for 2025.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2022 to 2024. Supported for 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.