Ford F-150 Lightning

Drivetrain parameters

The Ford F-150 Lightning has 5 drivetrain parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Primary motor coil temperature LIGHTNING_PRI_MOTOR_COIL_TConfirmed

  • Request22 48 1F
  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0017 = 23 → 23 °C

Formula
val
Range
-40 to 300 °C
Unit
°C

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Primary motor coil temperature LIGHTNING_PRI_MOTOR_COIL_TConfirmed

  • Request22 48 1F
  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0017 = 23 → 23 °C

Formula
val
Range
-40 to 300 °C
Unit
°C

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Primary motor inverter temperature LIGHTNING_PRI_MOTOR_INV_TConfirmed

  • Request22 48 24
  • Service 22DID 4824
  • Module7E6 → 7EE
  • Every5 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0021 = 33 → 33 °C

Formula
val
Range
-40 to 300 °C
Unit
°C

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Primary motor inverter voltage LIGHTNING_PRI_MOTOR_INV_VConfirmed

  • Request22 48 1D
  • Service 22DID 481D
  • Module7E6 → 7EE
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0018 = 24 → (24 ÷ 10) = 2.4 V

Formula
(val ÷ 10)
Range
-400 to 400 V
Unit
V

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Primary motor speed LIGHTNING_PRI_MOTOR_RPMConfirmed

  • Request22 1E 2C
  • Service 22DID 1E2C
  • Module7E6 → 7EE
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → 0 rpm

Formula
val
Range
-6000 to 12000 rpm
Unit
rpm

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Primary motor torque LIGHTNING_PRI_MOTOR_TQConfirmed

  • Request22 48 1C
  • Service 22DID 481C
  • Module7E6 → 7EE
  • Every1 s
  • Testing for 2003, 2022, 2024

Example reply from a 2025 Ford F-150 Lightning.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 10) = 0 N·m

Formula
(val ÷ 10)
Range
-200 to 200 N·m
Unit
N·m

Confirmed for 2023, 2025. In testing for 2003, 2022, 2024.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.