Hyundai Santa Cruz

Fuel parameters

The Hyundai Santa Cruz has 30 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Fuel level, volume SANTA_CRUZ_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 B0 02
  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2021, 2026

Example reply from a 2025 Hyundai Santa Cruz.

Bits 32 to 39 of the reply, 8 bits.

0x0E = 14 → (14 ÷ 2) = 7 L

Formula
(val ÷ 2)
Range
0 to 127.5 L
Unit
L

Confirmed for 2022 to 2025. In testing for 2021, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Cycle fuel consumption SANTA_CRUZ_CYCLE_FUEL_CONSConfirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2022, 2024, 2026

Example reply from a 2025 Hyundai Santa Cruz.

Bits 416 to 423 of the reply, 8 bits.

0x2F = 47 → (47 × 8.478 ÷ 100) = 3.98466

Formula
(val × 8.478 ÷ 100)
Range
0 to 21.6189
Unit
Raw value

Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Request01 9E
  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2023.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Request01 5E
  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3212.75 L/h
Unit
L/h

Confirmed for 2022 to 2023, 2025.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2023.

Fuel cut SANTA_CRUZ_FUEL_CUT_7E0Confirmed

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021, 2026

Example reply from a 2025 Hyundai Santa Cruz.

Bits 64 to 71 of the reply, 8 bits.

0xF1 = 241 → 241

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2022 to 2025. In testing for 2021, 2026.

Fuel level input SANTA_CRUZ_FLI_INPUT

  • Request22 E0 07
  • Service 22DID E007
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553 L
Unit
L

In testing for 2021 to 2024, 2026. Not supported for 2025.

Fuel level, volume SANTA_CRUZ_FLI_VOLConfirmed

Pelican can show this parameter as the fuel tank level.

  • Request22 B0 02
  • Service 22DID B002
  • Module7C6 → 7CE
  • Every1 s
  • Testing for 2021, 2026

Example reply from a 2025 Hyundai Santa Cruz.

Bits 32 to 39 of the reply, 8 bits.

0x0E = 14 → (14 ÷ 2) = 7 L

Formula
(val ÷ 2)
Range
0 to 127.5 L
Unit
L

Confirmed for 2022 to 2025. In testing for 2021, 2026.

Fuel pressure set point deviation SANTA_CRUZ_FUEL_P_SET_POINT_DEVConfirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2022, 2024, 2026

Example reply from a 2025 Hyundai Santa Cruz.

Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

0xFFFD = -3 → (-3 × 53066 ÷ 10000) = -15.9198

Formula
(val × 53066 ÷ 10000)
Range
-173886.6688 to 173881.3622
Unit
Raw value

Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.

Fuel pressure, actual SANTA_CRUZ_FUEL_P_ACTConfirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2022, 2024, 2026

Example reply from a 2025 Hyundai Santa Cruz.

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

0x0C00 = 3072 → (3072 × 53067 ÷ 10000) = 16,302.1824

Formula
(val × 53067 ÷ 10000)
Range
0 to 347774.5845
Unit
Raw value

Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.

Fuel pressure, set point SANTA_CRUZ_FUEL_P_SET_POINT_7E0Confirmed

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 2021 to 2022, 2024, 2026

Example reply from a 2025 Hyundai Santa Cruz.

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

0x0C00 = 3072 → (3072 × 53067 ÷ 10000) = 16,302.1824

Formula
(val × 53067 ÷ 10000)
Range
0 to 347774.5845
Unit
Raw value

Confirmed for 2023, 2025. In testing for 2021 to 2022, 2024, 2026.

Fuel system 1 status FUELSYS1SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2023. Supported for 2022, 2024 to 2025.

Fuel system 2 status FUELSYS2SAE J1979Confirmed

  • Request01 03
  • Service 01PID 03
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFEngine is off
1OLOpen loop - has not yet satisfied conditions to go closed loop
2CLClosed loop - using oxygen sensor(s) as feedback for fuel control
4OL-DriveOpen loop due to driving conditions (e.g. power enrichment, deceleration enleanment)
8OL-FaultOpen loop - due to detected system fault
16CL-FaultClosed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control
32OL B2Open loop - has not yet satisfied conditions to go closed loop (Bank 2)
64OL-Drive B2Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation)
128OL-Fault B2Open loop - due to detected system fault (Bank 2)

Confirmed for 2023. Supported for 2022, 2024 to 2025.

Fuel system A use percentage bank 1 FUELSYSA_B1SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023.

Fuel system A use percentage bank 2 FUELSYSA_B2SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023.

Fuel system A use percentage bank 3 FUELSYSA_B3SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023.

Fuel system A use percentage bank 4 FUELSYSA_B4SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 56 to 63 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023.

Fuel system B use percentage bank 1 FUELSYSB_B1SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023.

Fuel system B use percentage bank 2 FUELSYSB_B2SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023.

Fuel system B use percentage bank 3 FUELSYSB_B3SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023.

Fuel system B use percentage bank 4 FUELSYSB_B4SAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 71 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request01 2F
  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023 to 2025. Supported for 2022.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2023.

Fuel › Internal

Fuel system A use percentage bank 1 supported FUELSYSA_B1_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Fuel system A use percentage bank 2 supported FUELSYSA_B2_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Fuel system A use percentage bank 3 supported FUELSYSA_B3_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Fuel system A use percentage bank 4 supported FUELSYSA_B4_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Fuel system B use percentage bank 1 supported FUELSYSB_B1_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Fuel system B use percentage bank 2 supported FUELSYSB_B2_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Fuel system B use percentage bank 3 supported FUELSYSB_B3_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Fuel system B use percentage bank 4 supported FUELSYSB_B4_SUPSAE J1979Confirmed

  • Request01 9F
  • Service 01PID 9F
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.