Toyota Grand Highlander Hybrid
Battery parameters
The Toyota Grand Highlander Hybrid has 51 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
1st turbocharger outlet pressure, control valve GHH_1ST_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2023 to 2026.
2nd turbocharger outlet pressure GHH_2ND_TRUBOCHARGER_OUTLET_P
- Request
22 11 AF - Service 22
DID 11AF - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2023 to 2026.
2nd turbocharger outlet pressure, control valve GHH_2ND_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 2023 to 2026.
12V battery current GHH_12V_CConfirmed
- Request
22 15 F7 - Service 22
DID 15F7 - Module
7D2 → 7DA - Every
500 ms - Testing for 2023 to 2024, 2026
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 38.147 ÷ 10000 − 125)- Range
- -125 to 124 A
- Unit
- A
Confirmed for 2025. In testing for 2024, 2026.
12V battery temperature GHH_12V_TConfirmed
- Request
22 15 F8 - Service 22
DID 15F8 - Module
7D2 → 7DA - Every
1 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 Toyota Grand Highlander Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x01B7 = 439 → (439 ÷ 10 − 40) = 3.9 °C
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2025. In testing for 2024, 2026.
12V battery voltage GHH_12V_V_V2Confirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 15 EE - Service 22
DID 15EE - Module
7D2 → 7DA - Every
1 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 Toyota Grand Highlander Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x28 = 40 → (40 × 0.31448 + 0.0125) = 12.5917 V
- Formula
(val × 0.31448 + 0.0125)- Range
- 0 to 80.2 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
12V battery voltage before system main relay GHH_12V_BAT_V_BEFORE_SMR
- Request
22 10 7E - Service 22
DID 107E - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 61 ÷ 50000 + 11.25)- Range
- 0 to 11.56 V
- Unit
- V
In testing for 2024 to 2026.
12V battery voltage smoothed GHH_12V_BAT_V_SMOOTHED
- Request
22 1F 42 - Service 22
DID 1F42 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2024 to 2026.
Aux battery voltage GHH_AUX_BAT_V
- Request
22 10 02 - Service 22
DID 1002 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 61 ÷ 50000)- Range
- 0 to 79.95 V
- Unit
- V
In testing for 2024 to 2026.
Aux. battery capacity after IG OFF GHH_AUX_BAT_CAP_AFTER_IG_OFF
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2023 to 2026.
Aux. battery capacity after IG ON GHH_AUX_BAT_CAP_AFTER_IG_ON
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 2023 to 2026.
Auxiliary battery current GHH_AUXILIARY_BAT
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2525 ÷ 13107 − 12500)- Range
- -12500 to -12451 A
- Unit
- A
In testing for 2024 to 2026.
Battery current GHH_BAT_CURRENT_700
- Request
22 15 F7 - Service 22
DID 15F7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 49 ÷ 12850 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 2023 to 2026.
Battery status of full charge GHH_BAT_STAT_FULL_CHG
- Request
22 15 E5 - Service 22
DID 15E5 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 255 ÷ 2)- Range
- 0 to 32512.5 Ah
- Unit
- Ah
In testing for 2023 to 2026.
Battery temperature GHH_BAT_T_700
- Request
22 15 F8 - Service 22
DID 15F8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2023 to 2026.
Battery temperature GHH_BAT_T_700_2
- Request
22 1F F8 - Service 22
DID 1FF8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 2023 to 2026.
Battery voltage GHH_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 02 - Service 22
DID 1002 - Module
700 → 708 - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 Toyota Grand Highlander Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x28A8 = 10408 → (10408 × 12.207 ÷ 10000) = 12.705046 V
- Formula
(val × 12.207 ÷ 10000)- Range
- 0 to 79 V
- Unit
- V
Confirmed for 2025. In testing for 2023 to 2024, 2026.
Battery voltage GHH_BAT_V
- Request
21 13 - Service 21
PID 13 - Module
7C0 → 7C8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2023 to 2024, 2026. Not supported for 2025.
Charge contactor current GHH_SCC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2023 to 2024, 2026. Not supported for 2025.
Charging integrated current of aux. battery GHH_CHG_INTEGRATED
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2023 to 2026.
Dark current of battery GHH_DARK_CURRENT_BAT
- Request
22 15 E7 - Service 22
DID 15E7 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 2023 to 2026.
DC-DC converter high side voltage GHH_DC_DC_CONV_HIGH_SIDE_V
- Request
22 11 1E - Service 22
DID 111E - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 2024 to 2026.
DC-DC converter low side voltage GHH_DC_DC_CONV_LOW_SIDE_V
- Request
22 11 1D - Service 22
DID 111D - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1953 ÷ 25000)- Range
- 0 to 19.92 V
- Unit
- V
In testing for 2024 to 2026.
DC-DC converter, target voltage before charging GHH_DC_DC_CONV_TGT_V
- Request
22 11 1F - Service 22
DID 111F - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 1220703 ÷ 10000000)- Range
- 0 to 7999 V
- Unit
- V
In testing for 2024 to 2026.
Discharging integrated current of aux. battery GHH_DISCHARGING
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
3600 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 2023 to 2026.
Distance since last battery cable disconnection GHH_DIST_SINCE_BAT_DISCConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
700 → 708 - Every
30 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 Toyota Grand Highlander Hybrid.
Bits 0 to 15 of the reply, 16 bits.
0x3D55 = 15701 → 15,701 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2025. In testing for 2023 to 2024, 2026.
HV battery charge voltage GHH_HVBAT_CHRG_V
- Request
22 16 09 - Service 22
DID 1609 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 V
- Unit
- V
In testing for 2024, 2026. Not supported for 2025.
HV battery charge, maximum GHH_HVBAT_SOC_MAXConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 Toyota Grand Highlander Hybrid.
Bits 8 to 15 of the reply, 8 bits.
0x84 = 132 → (132 ÷ 2) = 66 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2024, 2026.
HV battery charge, minimum GHH_HVBAT_SOC_MINConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
7D2 → 7DA - Every
5 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 Toyota Grand Highlander Hybrid.
Bits 16 to 23 of the reply, 8 bits.
0x3C = 60 → (60 ÷ 2) = 30 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2024, 2026.
HV battery current GHH_HVBAT_CConfirmed
Pelican can show this parameter as the traction battery current.
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2023 to 2024, 2026
Example reply from a 2025 Toyota Grand Highlander Hybrid.
Bits 32 to 47 of the reply, 16 bits. The value is signed.
0x0070 = 112 → (112 ÷ 10) = 11.2 A
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 A
- Unit
- A
Confirmed for 2025. In testing for 2024, 2026.
HV battery maximum temperature GHH_HVBAT_MAX_T
- Request
22 18 29 - Service 22
DID 1829 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024, 2026. Not supported for 2025.
HV battery minimum temperature GHH_HVBAT_MIN_T
- Request
22 18 2A - Service 22
DID 182A - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2024, 2026. Not supported for 2025.
HV battery voltage GHH_HVBAT_VConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 1F 9A - Service 22
DID 1F9A - Module
7D2 → 7DA - Every
500 ms - Testing for 2023 to 2024, 2026
Example reply from a 2025 Toyota Grand Highlander Hybrid.
Bits 16 to 31 of the reply, 16 bits.
0x4600 = 17920 → (17920 × 156.25 ÷ 10000) = 280 V
- Formula
(val × 156.25 ÷ 10000)- Range
- 0 to 1023 V
- Unit
- V
Confirmed for 2025. In testing for 2024, 2026.
Hybrid battery 1 fan GHH_HYBRID_BAT_1_FAN
- Request
22 18 02 - Service 22
DID 1802 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2024 to 2026.
Hybrid battery temperature 1 GHH_HYBRID_BAT_T_1
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2024 to 2026.
Hybrid battery temperature 2 GHH_HYBRID_BAT_T_2
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2024 to 2026.
Hybrid battery temperature 3 GHH_HYBRID_BAT_T_3
- Request
22 18 14 - Service 22
DID 1814 - Module
7D2 → 7DA - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 458 ÷ 65535 − 58)- Range
- -58 to 400 °F
- Unit
- °F
In testing for 2024 to 2026.
Initial engine battery voltage lower limit GHH_INITIAL_ENG_BAT_V_LO
- Request
22 15 F6 - Service 22
DID 15F6 - Module
700 → 708 - Every
3600 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2023 to 2026.
Main connector solenoid current GHH_SMC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2023 to 2024, 2026. Not supported for 2025.
Main relay a, solenoid current GHH_SLA_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2023 to 2024, 2026. Not supported for 2025.
Main relay r solenoid current GHH_SLR_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2023 to 2024, 2026. Not supported for 2025.
Regenerative braking cooperation GHH_REGEN_COOPERATION
- Request
21 58 - Service 21
PID 58 - Module
7B0 → 7B8 - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2023 to 2024, 2026. Not supported for 2025.
Regenerative operation GHH_FR_REGEN_OPERATION
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2023 to 2024, 2026. Not supported for 2025.
Regenerative request GHH_FR_REGEN_REQUEST
- Request
21 48 - Service 21
PID 48 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 N·m
- Unit
- N·m
In testing for 2023 to 2024, 2026. Not supported for 2025.
Relay control solenoid current GHH_SRC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2023 to 2024, 2026. Not supported for 2025.
Service contactor solenoid current GHH_SSC_SOLENOID_CURRENT
- Request
21 A3 - Service 21
PID A3 - Module
7B0 → 7B8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
In testing for 2023 to 2024, 2026. Not supported for 2025.
Sleep time of battery sensor GHH_SLEEP_TIME_BATSENS
- Request
22 15 F0 - Service 22
DID 15F0 - Module
700 → 708 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 h
- Unit
- h
In testing for 2023 to 2026.
State of charge GHH_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 1F 5B - Service 22
DID 1F5B - Module
7D2 → 7DA - Every
1 s - Testing for 2023 to 2024, 2026
Example reply from a 2025 Toyota Grand Highlander Hybrid.
Bits 0 to 7 of the reply, 8 bits.
0x3B = 59 → (59 × 100 ÷ 255) = 23.137255 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2024, 2026.
Vh-voltage after boosting GHH_VH_V_AFTER_BOOSTING
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2024 to 2026.
Vl-voltage before boosting GHH_VL_V_BEFORE_BOOSTING
- Request
22 10 B0 - Service 22
DID 10B0 - Module
7D2 → 7DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 V
- Unit
- V
In testing for 2024 to 2026.
Voltage of battery sensor GHH_V_BATSENS
- Request
22 15 EE - Service 22
DID 15EE - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13333 ÷ 10922500)- Range
- 0 to 79.9979 V
- Unit
- V
In testing for 2023 to 2026.