Transmission fluid temperature, pan var.3 GHH_ATF_T_PAN_V3Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 16 27
  • Service 22DID 1627
  • Module700 → 708
  • Every5 s
  • Testing for 2023 to 2024, 2026

Example reply from a 2025 Toyota Grand Highlander Hybrid.

Bits 0 to 15 of the reply, 16 bits.

0x33E0 = 13280 → (13280 ÷ 256 − 40) = 11.875 °C

Formula
(val ÷ 256 − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. In testing for 2023 to 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Boosting converter temperature, lower GHH_BOOSTING_CONV_T_LO

  • Request22 10 A7
  • Service 22DID 10A7
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Boosting converter temperature, upper GHH_BOOSTING_CONV_T_HI

  • Request22 10 A7
  • Service 22DID 10A7
  • Module7D2 → 7DA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

DC-DC converter output current GHH_DC_DC_CONV_OUTPUT

  • Request22 11 1C
  • Service 22DID 111C
  • Module7D2 → 7DA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25 ÷ 32)
Range
0 to 199 A
Unit
A

In testing for 2024 to 2026.

Gear GHH_GEAR_700Confirmed

  • Request22 16 21
  • Service 22DID 1621
  • Module700 → 708
  • Every1 s
  • Testing for 2023 to 2024, 2026

Example reply from a 2025 Toyota Grand Highlander Hybrid.

Bits 0 to 7 of the reply, 8 bits.

0x01 = 1 → 1

Formula
val
Range
0 to 255
Unit
Number

Confirmed for 2025. In testing for 2023 to 2024, 2026.

Lock up state GHH_AT_LOCK_UP_STATE

  • Request22 16 20
  • Service 22DID 1620
  • Module700 → 708
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2023 to 2024, 2026. Not supported for 2025.

Transmission fluid post-converter temperature, variant 3 GHH_TRANS_FLUID_POST_T_3

  • Request22 16 28
  • Service 22DID 1628
  • Module700 → 708
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 256 − 40)
Range
-40 to 215.996 °C
Unit
°C

In testing for 2023 to 2026.

Transmission fluid temperature, pan var.3 GHH_ATF_T_PAN_V3Confirmed

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 16 27
  • Service 22DID 1627
  • Module700 → 708
  • Every5 s
  • Testing for 2023 to 2024, 2026

Example reply from a 2025 Toyota Grand Highlander Hybrid.

Bits 0 to 15 of the reply, 16 bits.

0x33E0 = 13280 → (13280 ÷ 256 − 40) = 11.875 °C

Formula
(val ÷ 256 − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2025. In testing for 2023 to 2024, 2026.

Transmission shift state ratio GHH_TRANS_SHIFT_ST_RAT

  • Request22 16 22
  • Service 22DID 1622
  • Module700 → 708
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5333 ÷ 21845000)
Range
0 to 15.999
Unit
Number

In testing for 2023 to 2026.

Transmission shift state ratio GHH_TRANS_SHIFT_ST_RAT_701

  • Request22 16 22
  • Service 22DID 1622
  • Module701 → 709
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5333 ÷ 21845000)
Range
0 to 15.999
Unit
Number

In testing for 2023 to 2026.